For proprietary products like Hydrocide 700B, confirm compatibility in the SDS and supplier guidance, then select low-shear pumping with corrosion-resistant wetted parts. Commonly, stainless steel or coated iron internals are used, with elastomers selected for pH and additive package resistance. Mechanical seals should be designed for emulsions: avoid high face pressure and choose seal faces that tolerate fine solids, with flush plans where needed. Use slow speed progressive cavity, diaphragm, or low-shear centrifugal designs, and avoid gear pumps unless the supplier approves shear and heat limits.